In the use of outdoor led display, often appear to be unable to load phenomenon. Led display manufacturer Ying Bao electronics from the following aspects to analyze the reason why the led display is not loaded.
1. Check if the jumper cap is loose or loose; if the jumper cap is not loose, make sure the jumper cap is in the correct direction.
2. Check that the serial cable used to connect the controller is a straight through cable, not a crossover cable.
3. Check and confirm that the serial port cable is intact and the two ends are not loose or fall off.
4. Select the correct product model, the correct transmission method, the correct serial port number, the correct serial transmission rate, and correctly set the dial switch map provided in the software by referring to the led display control software and the control card of your choice. Control system hardware address bits and serial transmission rate.
5. Ensure that the control system hardware is properly powered up.
6. If after the above check and correction still occurs, please use a multimeter to measure if the serial port of the connected computer or control system hardware is damaged. To confirm whether the computer manufacturer should be returned or return the control system hardware to the test.
In short, the reason why the LED display is not properly loaded may be the product itself, or it may be caused by improper operation during use. It is easy to find the source of the problem as long as you think or ask the manufacturer seriously.

Mobile hospical are widely used now in modern society. No matter emergencies, or disaster savings, all rescue actions will need mobile hospticals. Tentcool Mobile Field Hospital and Medical Air Conditioners help to improve the environment for doctors, patients and the medical equipments.

Tent Air Conditioner For Medical

Features:


  • High Mobility
  • Wide Applications
  • Easy to install and operate
  • Transport along with the vehicle


Optional Functions:

  • Custom painting
  • HEAT PUMP mode
  • Electric heating
  • High efficiency filter
  • Different supply voltages or frequency




Mobile Field Hospital Air Conditioner

               Certification:

                    ISO9001
                    ISO14001
                    CE Certified

             


                Spare parts warranty of 24 months

                After sales services and maintenance on demand.









Technical Data:

Model No. TTAC-07HCWa TTAC-07HCWa TTAC-12HCWaS TTAC-12HCWaS TTAC-18HCWaS TTAC-18HCWaS TTAC-40HCWaS TTAC-70HCWaS
Type Horizontal Vertical Horizontal Vertical Horizontal Vertical Horizontal Horizontal
Cooling capacity kW 7.00 7.00 12.00 12.00 18.00 18.00 40.00 70.00
Heating capacity  kW 7.70 7.70 13.50 13.50 19.50 19.50 45.00 77.00
Electric Heating kW 3.00 3.00 4.00 4.00 6.00 6.00 8.00 15.00
Rated cooling power input W 2550 2550 4150 4150 7000 7000 17500 30200
Rated heating power input W 2650 2650 4450 4450 8500 8500 18500 31400
Rated cooling current input A 12.2A 12.2A 7A 7A 11.7A 11.7A 29.5A 51.1A
Rated heating current input A 12.7A 12.7A 7.5A 7.5A 13.2A 13.2A 31.2A 53.0A
Evaporating side airflow m3h 1000 1000 2000 2000 3000 3000 5500 5500
Condensing side airflow m3h 3500 3500 5000 5000 10000 10000 22000 22000
Air pressure Pa 200 200 200 200 200 200 200 200
Compressor MFG GMCC GMCC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC PANASONIC
Evaporating side Noise dB(A) ≤40   ≤40   ≤45   ≤45   ≤48   ≤48   ≤52   ≤52  
Condensing side Noise dB(A) ≤55   ≤55   ≤60   ≤60   ≤65   ≤65   ≤70   ≤72
Net Weight kg 110 125 180 200 250 260 380 780
Dimension  (L x W x H))  mm 1150×710×820 740*620*1120  1280×930×1000 835*735*1275 1400×1080×980 930*850*1380 2100*1100*1210 2800*2100*1210