Slewing Bearing is a kind of
can bear larger axial load, radial load and tilting moment, a comprehensive
load bearing, rotating, transmission, fixed, and other functions in one of the
special structure of large bearing.In general, the slewing bearing itself is
equipped with mounting hole, lubricating oil and sealing device, which can meet
the different needs of various hosts working under various working conditions.
on the other hand, slewing bearing has a compact structure, easy to guide the
rotation, convenient installation and easy maintenance etc, are widely used in
lifting the transport machinery, mining machine, construction machinery, port
machinery, wind power generation, medical equipment, the radar and missile
launcher and other large rotary device.
Application of slewing bearing:
Engineering machinery, various
equipment platforms, trailers, wind power, solar energy, medical devices,
robots.
Full types of slewing bearing as below:
Single row four-point contact
ball slewing bearing,
Double different diameter ball
slewing bearing
Single row cross roller
slewing bearing,
Three row roller slewing
bearing
Single row four-point contact
ball slewing bearing (QU, QW, QN series)
Single row four-point contact
ball slewing bearing.
Single row four-point contact
ball slewing bearing.
Four point contact slewing
bearing (VL series)
Four point contact slewing
bearings (VS series)
Four point contact slewing
bearing (V series)
Single row cross roller
slewing bearing (XS series)
Single row cross roller
slewing bearing (X series)
We believe that we can supply the best service and price for your, hope to make a long-term cooperation with you. If you have any question please do not hesitate contact with us. We keep warmly welcome you visit us in any time.
Slewing Bearing Slewing Bearing,Roller Bearing,Slew Ring Gear,Ball Bearing Turntable LUOYANG AUTO BEARING CO.,LTD , https://www.lyautobearing.com
I. The products of Safe Lifeline are carefully designed and manufactured so that they can be safely and reliably operated. However, safe operation still requires the use and maintenance of the machine's staff. The following precautions, if followed carefully, will reduce the accident rate of the machine within the service life. Only trained and authorized personnel can operate the compressor. These people should read the manual carefully and fully understand it. Failure to follow the instructions, work procedures and safety precautions in the manual will result in accidents and even casualties. So be sure to read the operating manual before starting the air compressor. Unless it is safe, it must not be switched on; if it is known that there is a problem, do not start it. At this time, the power should be cut off or the drive must be removed and a mark must be made so that the unsuspecting person will not misoperation. The installation, use and operation of the machine shall strictly comply with the relevant local and local laws and standards. Do not change the device and control method unless written approval from the manufacturer. Note: See Appendix 1 for other safety precautions. Second, the air compressor station design principles 1, air compressor station design should consider the following factors: 1.1 close to the gas load center. 1.2 Power supply and supply are reasonable and convenient. 1.3 There is the possibility of expansion. 1.4 Avoid places that emit harmful substances such as explosive, corrosive and toxic gases and dust, and be located on the windward side of the above-mentioned places as much as possible. 1.5 The distance between the station room and the place where there is noise and vibration protection requirements shall comply with the current relevant regulations. 1.6 There should be enough space outside the air compressor station to ensure hot air discharge of the air compressor. 2. The air compressor station room should have enough space to ensure that the air compressor is no less than 1.5 meters from the top and no less than 2.5 meters from the top. And make sure: Air-cooled machine: 1.35M3/kw space; Water-cooled machine: 0.45M3/kw space. 3, air compressor station house should ensure that there is sufficient natural ventilation, try not to use the auxiliary room design, should use relatively independent station rooms, and try to avoid the West. The design of the air compressor station should take into account the smooth flow of air, the design requirements of the air intake of the engine room and the corresponding air intake of the compressor. The air flow rate of the air inlet should be controlled within 5m/s to avoid negative pressure in the machine room and ensure: Cooler: Ventilation window of 0.015M2/kw; Water cooler: Ventilation window of 0.006M2/kw. And ensure that the air compressor station room temperature does not exceed 40 degrees Celsius. 4, air compressor station room to meet the requirements of the air compressor and its auxiliary equipment installation base. Foundation requirements: The foundation should have enough strength, and the surface of the foundation should be flat and horizontal. The flatness should be controlled within 3mm. Ensure that the bottom of the foundation of the unit is fully grounded. For foundation construction, reference may be made to the size and weight of the hollow compressor in Schedule 1. The foundation size should be slightly larger than the size of the base of the compressor, and it should be more than 10 centimeters around. 5, air compressor station room should be reserved for access, maintenance access, in order to facilitate the entire machine access and maintenance. For a single air-pressure station with a displacement greater than or equal to 20 cubic meters and a total capacity greater than or equal to 60 cubic meters, lifting equipment for overhaul shall be provided. 6, air compressor station house should have necessary antifreeze, warm measures, consider installing heating. 7. The air compressor station should have reasonable drainage, drainage and drainage facilities. 8, air compressor station room to do a good cable pre-embedded, overhead cable routing. 9. Air compressor station houses should be soundproof and noise-reducing measures. If necessary, sound insulation materials can be installed on the walls of station buildings. 10. Compressed air tanks should be located outdoors, and should be located on the north side of the machine room, without affecting the lighting and ventilation. Gas tanks containing less than 1 mg/m3 of oil in compressed air can be placed indoors. Note: The People's Republic of China Standard GB 50029 â”2003 "Design Specification for Compressed Air Stations"