As the name implies, the oil temperature machine is a mold temperature machine using heat transfer oil as a heat transfer medium. The oil temperature machine itself is provided with an oil storage tank. When it is working, the heat transfer oil enters the system from the oil storage tank and is pumped into the mold or other equipment that needs to be controlled by the circulation pump. After the heat transfer oil comes out of the temperature controlled equipment, it returns to the system. Repeatedly. The heating oil heats up through the heater and stops when the temperature of the media detected by the temperature probe reaches a set value. When the temperature is lower than the set value, the heater starts to work, and when the temperature reaches the set value, it stops working again. This cycle.
Failure analysis and troubleshooting
1, the power indicator does not light after power
Possible causes: warranty burnout, main power failure, transformer damage, circuit board damage, and other line failures
Remedy: Replace insurance, check mains, replace transformers, worse circuit boards, check other circuits
2, After power on, the machine's reverse indicator light, buzzer alarm
Possible causes: The main power supply has a wrong phase sequence, the main power supply is missing phase, the internal wiring of the machine is wrong, and the main electrical control board is damaged.
Remedy: Interchange any two lines of the main power supply, check the mains voltage, check the internal wiring, replace the main control board
3, After the pump is turned on, the low level indicator lights and the pump does not start
Probable causes: The fuel tank is hot and the kerosene is insufficient, the replenishment pressure is insufficient (2KGF/CM2), and the low pressure value is set too high
Remedy: Fill the tank with hot kerosene until the alarm stops, increase the replenishment pressure until the alarm stops. Reset the low-pressure pressure switch until the alarm