Brass Thread Fitting,Brass PPR insert,Brass Compression Fitting,Brass PEX Fitting,Brass Pipe Couplings, brass push fit fitting, brass flange, brass PE-PPR fitting NINGBO YINZHOU PLUMBING HARDWARE CO.,LTD , https://www.brassvalve-china.com
Thermal Type Gas Mass Flowmeter utilizes the principle of heat exchange to measure fluid-flow. This meter employs method of constant temperature difference to accurately measure gas mass flow, and it has the advantages of small size, high degree of digitization, easy installation, accurate measurement, etc.
The sensor part consists of two platinum resistance converters of reference level. It utilizes bridge type loop circuit, with one converter measuring fluid temperature, and another maintaining constant temperature difference that is higher than fluid temperature. The measurement can be made under high temperature and high pressure situation. Â
Features:
-Calibrate output analog quantityÂ
- Directly measure gas mass flow, and gas temperature also can be output of the measuring system.
-Be adopted modular design method and operating principle to make the instrument higher measurement efficiency.
-Quick installation and manipulation menu allows the user easy to set parameters, and the instrument can flexibly display.
-It can cumulatively calculate flow and store the information in the EEPROM memory, and information will not be lost when power outage.
-Pressure drop or pressure loss can be negligible.
-Ratio of wide range can be 100:1.            Â
-It can be installed on the circular or rectangular pipe.
-Each instrument is individually calibrated, and it can be determined calibration scheme according to the requirement of user.
-Easy installation and maintenance. If possible, on line installations and maintenance are allowed.
-Ball valve accessories can be chose to remove or replace instrument easily in low pressure and non-toxic gas environment.
-Good anti-seismic performance and long useful life. The converter doesn't contain movable part and pressure sense part, so that the measuring accuracy is not influenced by shaking.
Applications:
Environmental protection , Petroleum , Petrochemical , power ,metallurgy , Chemical , food ,scientific research and other industries .
Technical parameters:
inline type
DN
Kg/h
Nm3/h
(0°C1.013bar atm)
Scf/min.
(15°C1.013bar atm)
Min.
Max.
Min.
Max.
Min.
Max.
15Â Â Â 0.5
53
0.38
41
0.23
25
25
2
200
1.5
155
1.0
96
40
6
555
4.6
429
3.0
266
50
10
910
7.7
704
5.0
436
80
20
2030
15.5
1570
10
974
100
38
3750
29
2900
18
1800
Â
insertion type
Â
DN
Kg/h
Nm3/h
(0°C1.013bar atm)
Scf/min.
(15°C1.013bar atm)
Min.
Max.
Min.
Max.
Min.
Max.
80
20
2030
15.5
1570
9.6
974
100
38
3750
29
2900
18
1800
150
50
7500
38
5800
24
3600
200
80
12500
62
9666
38
6000
250
120
20000
93
15468
58
9600
300
180
28000
139
21655
86
13440
400
300
50000
232
38670
144
24000
500
500
80000
386
61870
240
38400
600
700
115000
540
88940
336
55200
700
900
159000
696
122970
432
76300
1000
2000
320000
1546
247846
960
153600
1500
2500
720000
1933
556844
1200
345600
Flow range
0.2-120 Nm/s (air under the standard conditions)
Accuracy
Flow values:± 1% F · S, and plus 0.2% of reading
Temperature values: ±0.1°C
Repeatability
Flow values:± 0.5%
Temperature values: ±0.03°C
Range ratio
100:1 to 1000:1, the factory setting.
Temperature compensation
standard temperature compensation
Working temperature
-40 - +932 ° F (-40 - +500 °C)
Humidity
99%, non-condensing
Response time
0.75s
Temperature Effect
± 0.05% / °C
Operating pressure
10Mpa at 20 °C  9.5Mpa at 200 °C
Medium
All gases that can be compatible with material of flow components.
Environmental temperature
-40 - +160 ° F (-40 - +70 °C)
Storage temperature
-40 ° - +160 ° F (-40 - +70 °C)
Housing material
NAME4X (IP65) aluminum casting of powder coating
Process of connection
NPT or flange
Electrical interface
M20×1.5
Power supply
200-240VAC, 22-30VDC
Signal output
Current: 4-20mA, 700Ω maximum load
Voltage:0-10VDC, 200ohm, 1-5VDC, 100 maximum load
Communications
485, HART, Profibus, CAN optional
Â
Â
                Â
Model NO.: JH-RSFM-F
Measuring Media: Gas
Measuring Principle: Thermodynamic
Measurement Object: Closed Pipeline
Certification: CE, RoHS, ISO
Measuring Range: 1.2-200000m3/H
Power Supply: 220VAC
Signal Output: RS485,RS232,4-20mA
Display: LCD
Material: Ss316
Working Temperature: -20-350c
Anti-Explosion: Exdllct4
Protective Class: IP67
Trademark: JH
Transport Package: Carton
Specification: CE, ROHS
Origin: Shanghai
HS Code: 902610000
                              Thermal Gas Mass Flow Meter Â
We supply different type of Brass Compression Fitting. We are manufacturer and supplier of brass pex-al-pex coupling, brass PE-PPR coupling, brass push-in fitting, Brass Pex fitting ,PE compression fitting. Good price and service for Europe and America market.
Size: 15mm-63mm
Material: CuZn39Pb3, CuZn40Pb2, DZR.
Natural color or Plated nickel