Fault 1: power does not move Cause analysis: bad power connection; power supply voltage changes are not allowed within the scope of the coil short circuit or burnout: connect the power cord; adjust the voltage within the normal range; replace the coil fault two: open the valve The fluid can not pass the analysis: fluid pressure or working pressure does not meet; fluid viscosity or temperature does not conform to; plug valve core and moving around the mixing of dirt, impurities; valve pre-filter or pilot valve hole plugging; operating frequency too High or life-expired treatment: adjust the pressure or working pressure or replace the appropriate product; replace the appropriate product; internal cleaning, the valve must be installed before the filter valve; timely cleaning filter or pilot valve hole; re-election model or product Replacement of new products Failure three: the valve can not cut off the fluid Cause Analysis: Fluid viscosity does not meet; fluid temperature does not comply with; spring deformation or the end of life; seat defects or adhesion stolen goods; seal out prolapse or deformation; balance Hole or orifice clogged; use of the working frequency is too high or life expectancy Treatment: replacement of suitable products; replacement Of the products; add gaskets or replace the spring; cleaning, grinding or updating; update, re-assembly; timely cleaning; re-election model or new product replacement Fault 4: Analysis of leakage reasons: loose pipe connections; Failure to deal with: Tighten the bolt or take over the thread; replace the seal Fault 5: severe leak Cause Analysis: fluid temperature does not meet; pilot seat and the main valve seat impurities or defects; pilot valve and the main valve gasket prolapse or deformation; Spring assembly is not good, deformation or life expectancy; operating frequency is too high Handling methods: adjust the fluid temperature or replacement; if the cleaning or grinding repair or replacement; replacement of gaskets; replace the spring; re-election model or replacement of new product failure Six: the noise is too large when the power is on Cause Analysis: Loose fasteners; Voltage fluctuations, not within the allowable range; Fluid pressure or working pressure is not suitable; Fluid viscosity does not meet; Armature suction surface with impurities Treatment: Tighten; Normal range; adjust the pressure or working pressure or replace the product; replace the suitable product; promptly clean

Needle roll equipment

Packaging film needle roll equipment, film needle roll equipment, plastic film automatic needle roll equipment, Opp film needle roll equipment, automatic needle roll equipment

Changzhou Puyisen Machinery Technology Co., Ltd. , https://www.pysmachine.com